SACM150-P TRANSLUCENT PANEL TISSUE (150g/m²)

  • saxobran
  • China

We found that lighter veils split under high bending drag, letting fibers bloom and water leak in. SACM150-P uses a tough 150g/m² glass web that stretches over sharp roof ribs without snapping, keeping your light panels clear and strong.

Get a quote? Send Inquiry Now

SACM150-P TRANSLUCENT PANEL TISSUE (150g/m²)

 Stops Rib Cracking. High Light Clarity.


SAXOBRAN® Our team designed SACM150-P because we saw roof panel makers scrap corrugated sheets when deep rib bends cracked open during forming. We found that lighter veils split under high bending drag, letting fibers bloom and water leak in. SACM150-P uses a tough 150g/m² glass web that stretches over sharp roof ribs without snapping, keeping your light panels clear and strong.


Industrial Pain Points Solved.

Fiberglass mat

Fiberglass mat

Rib Corner Cracking and Web Snapping

  • Deep corrugated roof ribs stretch surface tissue beyond its limit during continuous forming. Cheap veils tear at the rib crest, creating resin cracks, water leaks, and high panel scrap.

  • Engineered with high Machine Direction tensile strength (≥170 N/50mm) to handle heavy rib forming drag.It conforms over sharp rib angles without tearing or pulling thin at the corners.


Fiberglass mat

Hazy Panels and UV Fiber Bloom

  • Coarse glass fibers block sunlight and turn cloudy inside cured resin. Harsh roof heat destroys unprotected surface fibers, causing yellowing and dirty fiber bloom within months.

  • Uses an invisible acrylic binder that dissolves fast, maintaining ≥80% light transmission.Forms a thick resin barrier that seals fibers flat and blocks UV weather attack.


Engineered Characteristics

Fiberglass mat

High-Drape Rib Coverage

Flexes smoothly over steep industrial roof rib profiles without tearing or springing back off the mold.

Fiberglass mat

Fast Capillary Wet-Out

Soaks up polyester resin in under 10 seconds to stop air bubbles and micro-pinholes on fast panel lines.

Fiberglass mat

Weather-Lock Barrier

Seals structural glass fibers beneath a rich resin top layer to stop fiber bloom and severe UV yellowing.


Technical Specifications Table


Technical ParameterStandard ValueTesting BasisEngineering Purpose
Area Weight (Grammage)150 g/m² (±5%)ISO 3374Secures heavy rib coverage while keeping high light transmission
MD Tensile Strength≥170 N/50mmISO 3342Prevents web tears when forming deep corrugated roof profile ribs
Light Transmission≥80% (in cured resin)ASTM D1003Delivers bright, clear daylighting through industrial factory roofs
Resin Wet-Out Time≤10 secondsISO 3374 (modified)Eliminates air pockets inside steep rib bends on continuous lines
Moisture Content≤0.15%ISO 3344Stops steam bubbles and internal haze during heat-curing stages
Binder Content5.5% - 8.5%ISO 1887Dissolves fast in styrene without leaving white binder ghost streaks

Processing, Packaging & Logistics Quality


1

Temperature Range

Store rolls in dry, indoor rooms kept between 10°C and 35°C.

2

Humidity Limits

 Maintain relative humidity below 65% to stop binder clumping.

3

Stacking Security

Stack pallets no more than 2 layers high to keep cardboard cores round.

Global Supply Chain Securement

  • Roll & Core Construction: Wound tight on heavy-duty 3-inch solid paper cores to prevent roll crushing.

  • Sealed Barrier Packaging: Sealed in thick, heat-shrink PE film to block sea moisture during transport.

  • Anti-Shifting Loading: Packed on strong wooden pallets with rigid corner boards and tight nylon straps.

Technical Q&A


Q: What is the fundamental difference in design logic between this model and the standard or general-purpose models within this category?

  • A: Standard translucent panel veils (like 30g/m² or 100g/m²) work well on flat or low-wave skylights. SACM150-P is engineered specifically for deep industrial roof ribs. Its heavier 150g/m² weight provides the extra tensile strength and thickness needed to stretch over high trapezoidal ribs without tearing, offering double the UV weather protection for heavy-duty industrial roofing.

Q: In the practical application of Industrial Roof Ribs, how should this model be utilized to achieve optimal performance?

  • A: Ensure your resin bath temperature stays between 25°C and 35°C to achieve complete binder dissolution before the sheet enters the rib-forming dies. Adjust guide roll tension so SACM150-P drapes evenly across the full width without off-center tracking. This allows the tissue to flow smoothly into the rib crests without creating stress wrinkles.

Q: What are the shelf life and storage limitations after opening the original packaging?

  • A: Once you cut the PE film seal, use the roll within 24 hours. Open glass tissue absorbs room humidity quickly. If moisture levels rise above 0.15%, trapped water creates micro-voids and cloudiness inside the resin when heated in gel ovens. Always wrap partially used rolls back in original PE film.


Get the latest price? We'll respond as soon as possible(within 12 hours)
  • Required and valid email address
  • This field is required
  • This field is required
  • This field is required
  • This field is required